Stationary Transducers - Analog
Product details
These n-gineric Analog stationary transducers ensure fastening accuracy and quality control on your manufacturing lines. Can be used with discontinuous drive tools, direct drive, oil pulse and mechanical pulse tools . Validate and verify accuracy and repeatability of assembly tools. Software included at no extra expense.
Key features
- Analog - Threaded USB connector - Requires analog interface cable (01-90-00021-01
- Analog output - 0 to 5 V, zero point at 2.5 V - 0 to 10 V, zero point at 5 V
- Verifies torque range from 1 cNm – 50 Nm
- External measuring device required
Analog Stationary Transducers
Model Number |
Torque Range |
Interface |
Drive Type |
Overload Protection |
---|---|---|---|---|
ng-TTS01-ca |
+/- 1 cNm |
Analog |
3mm Bore |
✔ |
ng-TTS02-ca |
+/- 2 cNm |
Analog |
3mm Bore |
✔ |
ng-TTS05-ca |
+/- 5 cNm |
Analog |
3mm Bore |
✔ |
ng-TTS10-ca |
+/- 10 cNm |
Analog |
3mm Bore |
✔ |
ng-TTS20-ca |
+/- 20 cNm |
Analog |
3mm Bore |
✔ |
ng-TTS50-xa |
+/- 50 cNm |
Analog |
1/4" Hex Drive |
✔ |
ng-TTS100-xa |
+/- 100 cNm |
Analog |
1/4" Hex Drive |
✔ |
ng-TTS200-xa |
+/- 200 cNm |
Analog |
1/4" Hex Drive |
✔ |
ng-TTS500-xa |
+/- 5 Nm |
Analog |
1/4" Hex Drive |
|
ng-TTS1000-xa |
+/- 10 Nm |
Analog |
1/4" Hex Drive |
|
ng-TTS2000-xa |
+/- 20 Nm |
Analog |
1/4" Hex Drive |
|
ng-TTS5000-qa |
+/- 50 Nm |
Analog |
3/8" Square Drive |
* 10 cNm = 0.1 Nm / 100 cNm = 1 Nm / 1000 cNm = 10 Nm