N325E HIT® Black Series AC Module (Commercial) New

VBHN325KA03E

Product details

N325E Black Series AC Module combines the efficiency of HIT® solar panels with the intelligence of Enphase microinverters. An Enphase IQ 7X microinverter with Individual MPPT tracking (Module-level Power Point Tracker) is integrated with HIT® high efficiency solar technology to deliver maximum power production from every roof size and shape. Featuring a 19.7 module efficiency and 325 watts per panel, the N325E alternative energy source offers extreme efficiency and high power output for residential solar systems.

Panasonic HIT® residential solar panels are backed by our complete TripleGuard warranty that guarantees minimum power output of 90.76% after 25 years and covers performance, parts, and labor for 25 years.*

*When installed by a Panasonic Authorized or Premium installer

Key features
  • High module efficiency of 19.7% provides 325W of high power output and greater energy yields
  • A low temperature coefficient of -0.258%/°C produces higher output at high temperatures
  • Remarkably low annual degradation ¬@ 0.26% with superior curb appeal
  • Highest PTC to STC rating for an AC module
  • Complete 25-year TripleGuard warranty on linear power output, parts, labor and product workmanship*

Model VBHN325KA03E
Peak Power Output 320VA
Maximum Continuous Output Power 315VA
Nominal (L-L) voltage/range† 240V / 211 – 264V
Maximum Continuous Output Current 1.31A 240VAC / 1.51A 208VAC
Maximum Units per 20 A (L-L) branch circuit 12 240VAC / 10 208VAC
Nominal Frequency 60Hz
Extended Frequency Range 47 – 68Hz
AC Short Circuit Fault Current Over 3 Cycles 5.8Arms
Overvoltage Class AC Port III
AC Port Backfeed Current 0A
Power Factor Setting 100%
Power Factor (adjustable) 0.85 leading / 0.85 lagging
CEC Weighted Efficiency 97.5% @ 240V / 96.5% 208V
Rated Power (Pmax)¹ 325W
Temperature Coefficient (Pmax) -0.258%/°C
CEC PTC Rating (Tentative) 302.4W
CEC PTC to STC Ratio (Tentative) 93.05%
Cell Efficiency 21.84%
Module Efficiency 19.4%
Warranted Tolerance (-/+) +10%/-0%*
Communication Communication Enlighten Manager and MyEnlighten monitoring options. Compatible with Enphase IQ Envoy
Communication Safety & Rating Certifications UL 1703, UL 1741, CEC. This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015. Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer’s instructions
Disconnecting means Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690.
Compliance Safety & Rating Certifications UL 1703, UL 1741, CEC. This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015. Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer’s instructions
Internal Bypass Diodes 4 Bypass Diodes
Module Area 18.02 Ft.² (1.67m²)
Weight 42.99 Lbs. (19.5kg)
Dimensions LxWxH 62.6x41.5x1.6 in. (1590x1053x40 mm)
Static Wind / Snow Load 112 PSF (5400Pa)
Pallet Dimensions LxWxH 65.3 x 43.7 x 48.5 in.
Quantity per Pallet / Pallet Weight 24 pcs./1098 Lbs. (498 kg)
Quantity per 40’ Container 672 pcs.
Quantity per 20’ Container 288 pcs.
Operating temperature -22ºF to 185ºF (-30ºC to 85ºC) [VBHN325KA03E]
Hail Safety Impact Velocity 1" hailstone (25mm) at 52 mph (23m/s)
UL 1703 Fire Classification Type 2
Limited Warranty Module and Microinverter: 25** Yrs Workmanship, Materials and Power. Output (Linear*** )
Manufacturing Locations USA